{"id":30605,"date":"2023-07-03T17:17:12","date_gmt":"2023-07-03T11:47:12","guid":{"rendered":"https:\/\/www.thermodyneboilers.com\/?p=30605"},"modified":"2023-07-03T17:17:13","modified_gmt":"2023-07-03T11:47:13","slug":"boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance","status":"publish","type":"post","link":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/","title":{"rendered":"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance"},"content":{"rendered":"\n<p>Steam flow rate (kg\/hour), pressure (kg\/cm\u00b2), temperature (\u00b0C) are all vital parameters that every boiler owner should monitor. In addition, fuel consumption, air temperature and pressure, flue gas measurements, feedwater temperature and quantity, blowdown duration, soot blowing, water treatment, and various instrumentation are all essential for maintaining a well-functioning boiler system. Let&#8217;s delve deeper into why boiler log sheets are indispensable for any boiler owner and how they contribute to efficiency and safety.<\/p>\n\n\n\n<p class=\"has-text-align-left\"><strong>Why are Boiler Log Sheets Important?<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\"><\/ol>\n\n\n\n<p>Boilers play a crucial role in many industrial processes, ranging from power generation to manufacturing. They produce steam, which is used for heating, powering turbines, or other applications. To ensure their smooth operation, it&#8217;s essential to maintain and monitor various parameters regularly. Boiler log sheets serve as a comprehensive record of these parameters, allowing owners to identify any deviations, abnormalities, or inefficiencies promptly.<\/p>\n\n\n\n<p><strong>Steam Parameters<\/strong><\/p>\n\n\n\n<p>Steam is the primary output of a boiler system. Monitoring steam parameters helps ensure the optimal performance of the boiler. The log sheet should include the following details:<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_68 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<p class=\"ez-toc-title\">Table of Contents<\/p>\n<label for=\"ez-toc-cssicon-toggle-item-69ecde5a7a1c3\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #707070;color:#707070\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #707070;color:#707070\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-69ecde5a7a1c3\" checked aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#flow-rate-kghour\" title=\"Flow Rate (kg\/hour)\">Flow Rate (kg\/hour)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#pressure-kgcm%c2%b2\" title=\"Pressure (kg\/cm\u00b2)\">Pressure (kg\/cm\u00b2)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#temperature-%c2%b0c\" title=\"Temperature (\u00b0C)\">Temperature (\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#fuel-consumption\" title=\"Fuel Consumption\">Fuel Consumption<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#fuel-%e2%80%93-oil\" title=\"Fuel &#8211; Oil\">Fuel &#8211; Oil<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#fuel-%e2%80%93-coalbiomasswood\" title=\"Fuel &#8211; Coal\/Biomass\/Wood\">Fuel &#8211; Coal\/Biomass\/Wood<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#air-parameters\" title=\"Air Parameters\">Air Parameters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#ambient-temperature-%c2%b0c\" title=\"Ambient Temperature (\u00b0C)\">Ambient Temperature (\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#temperature-at-air-preheater-outlet-%c2%b0c\" title=\"Temperature at Air Preheater Outlet (\u00b0C)\">Temperature at Air Preheater Outlet (\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#air-preheater-outlet-temperature-%c2%b0c\" title=\"Air Preheater Outlet Temperature (\u00b0C)\">Air Preheater Outlet Temperature (\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#economizer-inlet-temperature-%c2%b0c\" title=\"Economizer Inlet Temperature (\u00b0C)\">Economizer Inlet Temperature (\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#economizer-outlet-temperature-%c2%b0c\" title=\"Economizer Outlet Temperature (\u00b0C)\">Economizer Outlet Temperature (\u00b0C)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#co-content\" title=\"CO Content (%)\">CO Content (%)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#stack-appearance-descriptionremarks\" title=\"Stack Appearance (Description\/Remarks)\">Stack Appearance (Description\/Remarks)<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"flow-rate-kghour\"><\/span>Flow Rate (kg\/hour)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The flow rate of steam indicates the amount of steam being produced per hour. It is a critical parameter for assessing the boiler&#8217;s capacity and efficiency<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"pressure-kgcm%c2%b2\"><\/span>Pressure (kg\/cm\u00b2)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Steam pressure is another vital parameter that needs constant monitoring. Maintaining the correct pressure level is crucial for efficient operation and preventing any damage or safety risks.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"temperature-%c2%b0c\"><\/span>Temperature (\u00b0C)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Steam temperature directly affects the efficiency and performance of the system. Monitoring the temperature helps identify any variations that may impact the overall operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"fuel-consumption\"><\/span> Fuel Consumption<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Boilers can utilise different fuel sources such as oil, coal, wood, biomass or gas. Monitoring fuel consumption is crucial for managing costs, optimising efficiency, and detecting any fuel-related issues. The log sheet should include specific parameters for each fuel type.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"fuel-%e2%80%93-oil\"><\/span>Fuel &#8211; Oil<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>For oil-based boilers, track the flow rate (litres\/hr), temperature (\u00b0C), and oil pressure to the burner (kg\/cm\u00b2). These parameters help ensure the proper combustion of oil and prevent any malfunctions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"fuel-%e2%80%93-coalbiomasswood\"><\/span>Fuel &#8211; Coal\/Biomass\/Wood<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>If the boiler utilises any such solid fuel, monitoring the quantity consumed is vital. This information aids in fuel management and maintaining a consistent heat output.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"air-parameters\"><\/span>Air Parameters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Air plays a crucial role in the combustion process within the boiler. Monitoring air-related parameters helps optimise combustion efficiency and ensure safe operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"ambient-temperature-%c2%b0c\"><\/span>Ambient Temperature (\u00b0C)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The ambient temperature affects the density and oxygen content of the air. Keeping track of the ambient temperature helps maintain consistent combustion conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"temperature-at-air-preheater-outlet-%c2%b0c\"><\/span>Temperature at Air Preheater Outlet (\u00b0C)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Monitoring the air temperature at the outlet of the air preheater helps assess its efficiency and identify any potential issues that may affect the combustion process<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"air-preheater-outlet-temperature-%c2%b0c\"><\/span>Air Preheater Outlet Temperature (\u00b0C)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Monitoring the temperature at the air preheater&#8217;s outlet helps evaluate its performance and identify any potential issues that may impact heat transfer.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"economizer-inlet-temperature-%c2%b0c\"><\/span>Economizer Inlet Temperature (\u00b0C)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The temperature at the economizer&#8217;s inlet indicates the heat recovery efficiency. Monitoring this parameter helps optimise the boiler&#8217;s overall performance<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"economizer-outlet-temperature-%c2%b0c\"><\/span>Economizer Outlet Temperature (\u00b0C)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The temperature at the economizer&#8217;s outlet reflects the heat recovered from the flue gases. Tracking this parameter aids in assessing the economizer&#8217;s efficiency.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png\" alt=\"\" class=\"wp-image-30610\" width=\"922\" height=\"655\" srcset=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png 562w, https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1-300x213.png 300w\" sizes=\"(max-width: 922px) 100vw, 922px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"co-content\"><\/span>CO Content (%)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Monitoring the CO content in the flue gas at various points provides valuable information about the combustion process and the efficiency of the system.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"stack-appearance-descriptionremarks\"><\/span>Stack Appearance (Description\/Remarks)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>The appearance of the smoke at stack outlet and any associated remarks provide additional insights into the combustion process and potential issues with the system.<\/p>\n\n\n\n<p><strong>\u00a0Water Treatment<\/strong><\/p>\n\n\n\n<p>Water treatment is essential to prevent scale formation, corrosion, and fouling within the boiler. Monitoring water treatment parameters is crucial for maintaining water quality and protecting the boiler system.<\/p>\n\n\n\n<p><strong>\u00a0TDS Content (ppm)<\/strong><\/p>\n\n\n\n<p>Total Dissolved Solids (TDS) content indicates the level of impurities in the water. Monitoring TDS helps assess the effectiveness of the water treatment process.<\/p>\n\n\n\n<p><strong>Hardness (ppm)<\/strong><\/p>\n\n\n\n<p>Water hardness is a measure of the mineral content in the water. Monitoring hardness levels helps prevent scaling and related issues.<\/p>\n\n\n\n<p><strong>\u00a0pH<\/strong><\/p>\n\n\n\n<p>Maintaining the correct pH level is crucial for preventing corrosion and ensuring the longevity of the boiler system. Regular monitoring helps detect any deviations.<\/p>\n\n\n\n<p><strong>\u00a0Alkalinity (ppm)<\/strong><\/p>\n\n\n\n<p>Alkalinity levels in water affect the system&#8217;s pH and buffering capacity. Monitoring alkalinity ensures the proper functioning of the water treatment process.<\/p>\n\n\n\n<p><strong>Boiler Water<\/strong><\/p>\n\n\n\n<p>Recording additional parameters specific to boiler water, such as TDS content just before blowdown, hardness, phosphates, and sulphates, provides comprehensive information for water treatment assessment.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p><strong>Minimum Instrumentation Required in the Boiler House<\/strong><\/p>\n\n\n\n<p>The minimum instrumentation required in the boiler house ensures accurate measurement and monitoring of essential parameters. The log sheet should include:<\/p>\n\n\n\n<p><strong>Steam flow and integrating meter<\/strong><\/p>\n\n\n\n<p>Steam pressure gauges on the steam line<\/p>\n\n\n\n<p>Thermometer on the steam line<\/p>\n\n\n\n<p>Oil flow and integrating meter<\/p>\n\n\n\n<p>Thermometer on the oil line (before and after the heater)<\/p>\n\n\n\n<p>Pressure gauge on the oil line (just before the burner)<\/p>\n\n\n\n<p>Weighing machine for coal<\/p>\n\n\n\n<p><strong>Room thermometer<\/strong><\/p>\n\n\n\n<p>Thermometers (before and after the air preheater) for air and flue gas temperature<\/p>\n\n\n\n<p>Thermometers for water (inlet and outlet of economizer)<\/p>\n\n\n\n<p>CO meter (Orsat or Fyrite type)<\/p>\n\n\n\n<p>Thermometers to measure water temperatures at the inlet to feed pump<\/p>\n\n\n\n<p><strong>Stopwatch<\/strong><\/p>\n\n\n\n<p>Complete set of laboratory equipment in the laboratory to test water samples<\/p>\n\n\n\n<p>Ensuring the availability and proper functioning of these instruments contributes to accurate data collection and efficient boiler operation. For more informationation <a href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/download-boiler-bible\/\" target=\"_blank\" rel=\"noreferrer noopener\">download boiler bible <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Steam flow rate (kg\/hour), pressure (kg\/cm\u00b2), temperature (\u00b0C) are all vital parameters that every boiler owner should monitor. In addition, fuel consumption, air temperature and pressure, flue gas measurements, feedwater temperature and quantity, blowdown duration, soot blowing, water treatment, and various instrumentation are all essential for maintaining a well-functioning boiler system. Let&#8217;s delve deeper into <a class=\"read-more-link\" href=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/\">Read More<\/a><\/p>\n","protected":false},"author":10499,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[224],"tags":[],"class_list":["post-30605","post","type-post","status-publish","format-standard","hentry","category-steam-boiler"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance -<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance -\" \/>\n<meta property=\"og:description\" content=\"Steam flow rate (kg\/hour), pressure (kg\/cm\u00b2), temperature (\u00b0C) are all vital parameters that every boiler owner should monitor. In addition, fuel consumption, air temperature and pressure, flue gas measurements, feedwater temperature and quantity, blowdown duration, soot blowing, water treatment, and various instrumentation are all essential for maintaining a well-functioning boiler system. Let&#8217;s delve deeper into Read More\" \/>\n<meta property=\"og:url\" content=\"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermodyneBoilers\/\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-03T11:47:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-03T11:47:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.thermodyneboilers.com\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png\" \/>\n<meta name=\"author\" content=\"Thermodyne\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@https:\/\/twitter.com\/ThermodyneB\" \/>\n<meta name=\"twitter:site\" content=\"@DelhiThermodyne\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Thermodyne\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/\"},\"author\":{\"name\":\"Thermodyne\",\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#\\\/schema\\\/person\\\/01b4b6a70c236adb80870cc9dab8ba97\"},\"headline\":\"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance\",\"datePublished\":\"2023-07-03T11:47:12+00:00\",\"dateModified\":\"2023-07-03T11:47:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/\"},\"wordCount\":911,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Per-hour-fuel-consumption-1.png\",\"articleSection\":[\"Steam Boiler\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/\",\"url\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/\",\"name\":\"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance -\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Per-hour-fuel-consumption-1.png\",\"datePublished\":\"2023-07-03T11:47:12+00:00\",\"dateModified\":\"2023-07-03T11:47:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#primaryimage\",\"url\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Per-hour-fuel-consumption-1.png\",\"contentUrl\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Per-hour-fuel-consumption-1.png\",\"width\":562,\"height\":399},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Steam Boiler\",\"item\":\"https:\\\/\\\/www.thermodyneboilers.com\\\/category\\\/steam-boiler\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#website\",\"url\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/\",\"name\":\"\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#organization\",\"name\":\"Thermodyne Engineering Systems\",\"url\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/wp-content\\\/uploads\\\/2016\\\/10\\\/logo-1.png\",\"contentUrl\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/wp-content\\\/uploads\\\/2016\\\/10\\\/logo-1.png\",\"width\":208,\"height\":46,\"caption\":\"Thermodyne Engineering Systems\"},\"image\":{\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ThermodyneBoilers\\\/\",\"https:\\\/\\\/x.com\\\/DelhiThermodyne\",\"https:\\\/\\\/www.instagram.com\\\/thermodyneboilers\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/thermodyne-engineering-systems\",\"https:\\\/\\\/myspace.com\\\/thermodyneboiler\",\"https:\\\/\\\/in.pinterest.com\\\/Thermodyne\\\/\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/Thermodyneboiler\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/thermodyneboilers.com\\\/demo\\\/oldthermo\\\/#\\\/schema\\\/person\\\/01b4b6a70c236adb80870cc9dab8ba97\",\"name\":\"Thermodyne\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e9b78a7330ba255d86e01ffc9be84a62d6d540968e23b6d40d5b12e6dae48098?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e9b78a7330ba255d86e01ffc9be84a62d6d540968e23b6d40d5b12e6dae48098?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e9b78a7330ba255d86e01ffc9be84a62d6d540968e23b6d40d5b12e6dae48098?s=96&d=mm&r=g\",\"caption\":\"Thermodyne\"},\"description\":\"Thermodyne Engineering Systems is a leading manufacturer and exporter of boilers and heating equipment based in Ghaziabad, Uttar Pradesh, India. The company was founded in 2000 by Mr. Ashwani Setia and Mr. Amitabha Ghosh, both of whom have extensive experience in the boiler industry. Thermodyne's product range includes steam boilers, hot water generators, thermic fluid heaters, and waste heat recovery systems. The company serves a wide range of industries, including food processing, pharmaceuticals, chemicals, and textiles. Thermodyne has a state-of-the-art manufacturing facility spread over 10 acres, with a production capacity of up to 10,000 kg\\\/hr of steam. The company has a team of experienced engineers and technicians who are dedicated to delivering high-quality products and services. Thermodyne has a strong commitment to sustainability and energy efficiency. The company's products are designed to minimize energy consumption and reduce greenhouse gas emissions. Thermodyne has also implemented sustainable practices in its manufacturing processes, such as using solar energy for heating and lighting. In addition to its manufacturing operations, Thermodyne also provides a range of services, including installation, commissioning, and after-sales support. The company has a strong network of dealers and distributors across India and abroad, and is committed to delivering the best possible customer service.\",\"sameAs\":[\"https:\\\/\\\/www.thermodyneboilers.com\\\/\",\"https:\\\/\\\/www.instagram.com\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/thermodyne-boilers\\\/\",\"https:\\\/\\\/in.pinterest.com\\\/THERMODYNE11\\\/\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/ThermodyneB\",\"https:\\\/\\\/www.youtube.com\\\/@Thermodyneboilerss\",\"https:\\\/\\\/www.facebook.com\\\/ThermodyneBoilers\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance -","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance -","og_description":"Steam flow rate (kg\/hour), pressure (kg\/cm\u00b2), temperature (\u00b0C) are all vital parameters that every boiler owner should monitor. In addition, fuel consumption, air temperature and pressure, flue gas measurements, feedwater temperature and quantity, blowdown duration, soot blowing, water treatment, and various instrumentation are all essential for maintaining a well-functioning boiler system. Let&#8217;s delve deeper into Read More","og_url":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/","article_publisher":"https:\/\/www.facebook.com\/ThermodyneBoilers\/","article_published_time":"2023-07-03T11:47:12+00:00","article_modified_time":"2023-07-03T11:47:13+00:00","og_image":[{"url":"https:\/\/www.thermodyneboilers.com\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png","type":"","width":"","height":""}],"author":"Thermodyne","twitter_card":"summary_large_image","twitter_creator":"@https:\/\/twitter.com\/ThermodyneB","twitter_site":"@DelhiThermodyne","twitter_misc":{"Written by":"Thermodyne","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#article","isPartOf":{"@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/"},"author":{"name":"Thermodyne","@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#\/schema\/person\/01b4b6a70c236adb80870cc9dab8ba97"},"headline":"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance","datePublished":"2023-07-03T11:47:12+00:00","dateModified":"2023-07-03T11:47:13+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/"},"wordCount":911,"commentCount":0,"publisher":{"@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#organization"},"image":{"@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#primaryimage"},"thumbnailUrl":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png","articleSection":["Steam Boiler"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/","url":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/","name":"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance -","isPartOf":{"@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#primaryimage"},"image":{"@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#primaryimage"},"thumbnailUrl":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png","datePublished":"2023-07-03T11:47:12+00:00","dateModified":"2023-07-03T11:47:13+00:00","breadcrumb":{"@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#primaryimage","url":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png","contentUrl":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2023\/07\/Per-hour-fuel-consumption-1.png","width":562,"height":399},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermodyneboilers.com\/boiler-log-sheets-a-simple-way-to-ensure-boiler-compliance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.thermodyneboilers.com\/"},{"@type":"ListItem","position":2,"name":"Steam Boiler","item":"https:\/\/www.thermodyneboilers.com\/category\/steam-boiler\/"},{"@type":"ListItem","position":3,"name":"Boiler Log Sheets: A Simple Way to Ensure Boiler Compliance"}]},{"@type":"WebSite","@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#website","url":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/","name":"","description":"","publisher":{"@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#organization","name":"Thermodyne Engineering Systems","url":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#\/schema\/logo\/image\/","url":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2016\/10\/logo-1.png","contentUrl":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-content\/uploads\/2016\/10\/logo-1.png","width":208,"height":46,"caption":"Thermodyne Engineering Systems"},"image":{"@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ThermodyneBoilers\/","https:\/\/x.com\/DelhiThermodyne","https:\/\/www.instagram.com\/thermodyneboilers\/","https:\/\/www.linkedin.com\/company\/thermodyne-engineering-systems","https:\/\/myspace.com\/thermodyneboiler","https:\/\/in.pinterest.com\/Thermodyne\/","https:\/\/www.youtube.com\/user\/Thermodyneboiler"]},{"@type":"Person","@id":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/#\/schema\/person\/01b4b6a70c236adb80870cc9dab8ba97","name":"Thermodyne","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e9b78a7330ba255d86e01ffc9be84a62d6d540968e23b6d40d5b12e6dae48098?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e9b78a7330ba255d86e01ffc9be84a62d6d540968e23b6d40d5b12e6dae48098?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e9b78a7330ba255d86e01ffc9be84a62d6d540968e23b6d40d5b12e6dae48098?s=96&d=mm&r=g","caption":"Thermodyne"},"description":"Thermodyne Engineering Systems is a leading manufacturer and exporter of boilers and heating equipment based in Ghaziabad, Uttar Pradesh, India. The company was founded in 2000 by Mr. Ashwani Setia and Mr. Amitabha Ghosh, both of whom have extensive experience in the boiler industry. Thermodyne's product range includes steam boilers, hot water generators, thermic fluid heaters, and waste heat recovery systems. The company serves a wide range of industries, including food processing, pharmaceuticals, chemicals, and textiles. Thermodyne has a state-of-the-art manufacturing facility spread over 10 acres, with a production capacity of up to 10,000 kg\/hr of steam. The company has a team of experienced engineers and technicians who are dedicated to delivering high-quality products and services. Thermodyne has a strong commitment to sustainability and energy efficiency. The company's products are designed to minimize energy consumption and reduce greenhouse gas emissions. Thermodyne has also implemented sustainable practices in its manufacturing processes, such as using solar energy for heating and lighting. In addition to its manufacturing operations, Thermodyne also provides a range of services, including installation, commissioning, and after-sales support. The company has a strong network of dealers and distributors across India and abroad, and is committed to delivering the best possible customer service.","sameAs":["https:\/\/www.thermodyneboilers.com\/","https:\/\/www.instagram.com\/","https:\/\/www.linkedin.com\/in\/thermodyne-boilers\/","https:\/\/in.pinterest.com\/THERMODYNE11\/","https:\/\/x.com\/https:\/\/twitter.com\/ThermodyneB","https:\/\/www.youtube.com\/@Thermodyneboilerss","https:\/\/www.facebook.com\/ThermodyneBoilers"]}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"Thermodyne","author_link":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/author\/ravidm\/"},"uagb_comment_info":0,"uagb_excerpt":"Steam flow rate (kg\/hour), pressure (kg\/cm\u00b2), temperature (\u00b0C) are all vital parameters that every boiler owner should monitor. In addition, fuel consumption, air temperature and pressure, flue gas measurements, feedwater temperature and quantity, blowdown duration, soot blowing, water treatment, and various instrumentation are all essential for maintaining a well-functioning boiler system. Let&#8217;s delve deeper into&hellip;","_links":{"self":[{"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/posts\/30605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/users\/10499"}],"replies":[{"embeddable":true,"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/comments?post=30605"}],"version-history":[{"count":1,"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/posts\/30605\/revisions"}],"predecessor-version":[{"id":30611,"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/posts\/30605\/revisions\/30611"}],"wp:attachment":[{"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/media?parent=30605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/categories?post=30605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/thermodyneboilers.com\/demo\/oldthermo\/wp-json\/wp\/v2\/tags?post=30605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}